還真的要PO一篇好好說明一下
: ※ 引述《hvmcg (阿毛)》之銘言:
: 1) UV 跟 excition到底有什麼不一樣呢
: 為什麼同樣的東西我測出來的UV and ex會不一樣 ??
: 我知道UV是在液態中用一個波長一個波長打sample
: 看sample的吸收是多少
: 而ex是用em的波長當作參考 固定波長來打sample看激發的波長
: 此兩種到底是有哪兒不一樣阿? 不是都是激發嗎 ???
The relationship between Absorption and No. of molecule being excited (or
No. of photon being absorbed)
A = logIo/I = -logI/Io = -(1/2.303)*lnI/Io
其中Io = 入射光; I = 出射光 (就是入射光照射樣品出來的光)
A = -(1/2.303)*ln(Io-I')/Io I' = "被吸收之光量", I=Io-I'
= -(1/2.303)*ln(1-I'/Io)
if I'遠小於Io -> This holds true for A < 0.1 , ln(1-I'/Io)~-I'/Io
-> A = (1/2.303)*(I'/Io)
所以 I' = 2.303Io*A I'("被吸收之光量")正比於A
結論:當Absorbance很小時則光的被吸收量和Absorbance成正比
又 F (Fluorescence)正比於I'("被吸收之光量")
-> F 正比於 Absorbance
是故當您掃描一個Fluorescence excitation spectra時其光譜圖應該非常
類似於Absorption Spectra. 如果您做出的圖形和Absorption Spectra 不合
-> 可能有下列情形發生:
1.Absorbance太高以致I'不正比於Absorbance
2.Ground state不只一種Species
3.Fluorometer沒有被calibrated過
4.濃度太高以致光徑已被distorted掉
這是我以前上課時老師做的投影片內容
應該很容易了解吧
: 2) 如果我UV測出來有兩個吸收峰 那是表示ex也會有兩個吸收峰 ??
: 這句話是不是不對阿 因為我測ex只有一個吸收峰而已 就算是全掃瞄也一樣
: --
: 推 cooljeff19:吸收和放射是互為鏡影 不會重疊 04/18 00:12
: → cooljeff19:測ex和em通常是螢光光譜儀 UV是吸收光譜儀 04/18 00:14
: → cooljeff19:兩種儀器設計的原理基本上就不一樣了 翻書比較快 04/18 00:15
......, the excitation spectrum of a fluorophore is typically superimposable
on its absorption spectrum.
ref:Lakowicz, J. R. Principles of Fluoroscence Spectroscopy. 1999, 25-26.
...... The corrected excitation spectrum is thus identical in shape to the
absorption spectrum, provided that there is a single species in the ground
state.
ref:Valeur, B. Molecular Fluorescence: Principles and Applications. 2002,
52-53.
--
※ 發信站: 批踢踢實業坊(ptt.cc)
◆ From: 123.194.211.239
1F:推 AmnesiacVC:還有一個可能的問題是 吸收跟發光的機制不太一樣 04/18 01:17
2F:→ AmnesiacVC:不同激發波產生emissive species的quantum yield 04/18 01:19
3F:→ AmnesiacVC:也不見得一樣 @@" 所以PLE 不一定等於吸收 04/18 01:20
4F:→ AmnesiacVC:畢竟吸收完之後一系列的relaxation/ decay channel 04/18 01:22
5F:→ AmnesiacVC:可能都跟激發波長(激發態狀態)有關 04/18 01:23
6F:推 AmnesiacVC:另外 如果不只一種emissive species 04/18 01:26
7F:→ AmnesiacVC:PLE的圖譜 跟量測時選擇的發光波長也會有關 04/18 01:26
8F:推 cooljeff19:嗯 不過通常愛因斯坦係數A和B成正比啦 04/18 15:59
我這篇有扯到愛因斯坦的A B coefficient??
※ 編輯: ChallengerII 來自: 123.194.211.239 (04/20 00:15)
9F:推 cooljeff19:我是說A大的推文裡面 04/20 12:55
10F:推 jasonfghx:push 07/28 17:28