作者pseudo0405 (Kasim)
看板Examination
标题[考题] 中油97年新进职员单元操作第3题
时间Fri Oct 18 00:34:51 2013
抱歉,考题我就不列上来了,我只写出我的解答
砖壁排列为 (l800 oF) Fireclay (T1) insulating (T2) building (100 oF)
因为250 Btu/hr-ft2 > qt/A = (2000-100)/R
又Rt = R1 + R2 + R3 = (L1/0.90) + (L2/0.12) + (L3/0.40)
由於串联所以 qt/A = q1/A = q2/A = q3/A
因为insulating砖材耐热只有1800 oF
250 = (2000-1800) / (L1/0.90) 所以若Fireclay和insulating接触面要低於1800 oF的话
则L1至少要0.72*12 = 8.64 inch,故Fireclay砖材必须要两块
也就是实际上的L1 = 2*4.5 = 9 inch = 0.75 ft
(这里如果要算界面温度 250 = (2000-T1) / (9/12/0.90) 则T1 = 1791 oF,基本上这里
可以不用特别去算,因为0.72和0.75差不多,所以T1和1800 oF不会差太多)
因为building砖材耐热只有300 oF
250 = (1800-300) / (L2/0.12) 所以若insulating和building接触面要低於300 oF的话
则L2至少要0.72*12 = 8.64 inch,故insulating必须要3块
也就是实际上L2 = 3*3 = 9 inch = 0.75 ft
(这里同样因为0.72和0.75差不多,所以T2和300 oF不会差太多)
最後building
250 = (300-100) / (L3/0.40) 可得到L3 = 0.32*12 = 3.84 inch
故building必须要为1块,也就是实际上L3 = 4*1 = 4 inch = 1/3 ft
所以总和厚度L = L1 + L2 + L3 = 9 + 9 + 4 = 22 inch
实际热传通量qt/A = (2000-100) / [(0.75/0.90) + (0.75/0.12) + (4/12/0.40)]
= 240 Btu/hr-ft2
我的计算应该没有问题吧,还望各位多多指教,感谢~
--
※ 发信站: 批踢踢实业坊(ptt.cc)
◆ From: 1.163.139.84
1F:→ sweetycool:怎感觉好像是热传学的题目 10/18 00:52
2F:推 pj721911:一百分 10/18 09:03
3F:→ soulgel:100 10/18 12:01
4F:→ MSNboy:这题中兴有出过,去翻林隆的详解就有 10/18 13:34