作者CL2NE1 (CL)
看板Electronics
标题[问题] HSpice 参数输出问题 .param
时间Wed Jan 9 22:55:47 2013
大家好
想请教关於.param 参数输出的问题
如下spice档
主要是逆向操作 藉由输入暂态电流值
设通道迁移率 Un Width Length Vt ... 等数值已知
求出氧化层电容 Cox
**** for simulation
.option post
.param Wn=100u Ln=1u kn=75.3678u vt=0.570887 lambda=0.0026049
$ Wn Ln->MOS's width/length
.param vdss=1.2 vgss=1 IF=0 RR0=10 Un=500
.subckt large_signal drain gate source
.if (vdss == 0 || vgss == 0)
gds drain source cur='0'
.elseif (vdss < (vgss-vt))
* gds drain source cur='kn*(Wn/Ln)*(vgss-vt-(vdss/2))*vdss'
.param Cox=IF/(Un*100*((1-vt)-(vdss/2))*vdss)
.elseif (vdss>=(vgss-vt))
* gds drain source cur='0.5*kn*(Wn/Ln)*pwr((vgss-vt),2)*(1+(lambda*vdss))'
.param Cox=IF/(0.5*Un*100*pwr((1-vt),2))
.else
* gds drain source cur='0'
.endif
.ends
xt drain gate source large_signal
vds drain 0 dc 0
vgs gate 0 dc 3
vss source 0 dc 0
.dc vds 0 2 1
.probe i(xt.gds) Cox=par('Cox')
.print i(xt.gds) Cox=par('Cox')
.alter
.param IF= 0.00123
.alter
.param IF= 0.00123
.alter
.param IF= 0.00123
.alter
.
.
.
.
.end
debug後没有error
但却有如下所述
.param cox=if/(un*100*((1-vt)-(vdss/2))*vdss)
**warning** command in if ... else ... block defined in
subckt, ignored.
.elseif (vdss>=(vgss-vt))
gds drain source cur='0.5*kn*(wn/ln)*pwr((vgss-vt),2)*(1+(lambda*vdss))'
.param cox=if/(0.5*un*100*pwr((1-vt),2))
**warning** command in if ... else ... block defined in
subckt, ignored.
撰写的cox参数 直接被忽略掉
想请问关於if判断式内 是否不能直接设定参数定义
以及 .probe Cox=par('Cox') 这写法应该是正确吧?
感谢大家
--
※ 发信站: 批踢踢实业坊(ptt.cc)
◆ From: 163.17.10.169