作者BruceBowen12 (just defense)
看板Electronics
标题[问题] layout
时间Fri Aug 3 12:18:55 2007
各位前辈好
在做drc时出现以下的这个问题
T.3P { @ N-well pickup OD to PMOS space > 30um
NWELi_US = SIZE NWELi BY - 0.085 // 0.12/1.415 = 0.085
// 30/1.415 = 21.201, (0.6 + 2 * 0.085)/1.415 = 0.544
NTAP_OS = SIZE NTAP BY 21.201 INSIDE OF NWELi_US STEP 0.544 TRUNCATE 0.544
PASD_FAR = PASD NOT NTAP_OS
PASD_FAR_FILTER = SIZE PASD_FAR BY 30
NTAP_NEAR = NTAP INTERACT PASD_FAR_FILTER
// doing an more accurate sizing
NTAP_NEAR_OS = SIZE NTAP_NEAR BY 0.10
NTAP_90_CORNER = INT NTAP_NEAR_OS < 0.06 ABUT==90 INTERSECTING ONLY REGION
NTAP_OCT = NTAP_NEAR_OS NOT NTAP_90_CORNER
NTAP_135_CORNER = INT NTAP_OCT < 0.04 ABUT>134<136 INTERSECTING ONLY REGION
NTAP_HEX = NTAP_OCT NOT NTAP_135_CORNER
// 30-0.10 = 29.9
NTAP_HEX_OS = SIZE NTAP_HEX BY 29.9 INSIDE OF NWELi_US STEP 0.544 TRUNCATE 0.544
PASD_FAR NOT NTAP_HEX_OS
}
导致在做lvs时
找不到pmos body的电压
找了半天 不知道是那里出错了
我是用laker去画的
两个pmos的共用端 我是用叠起来的
外面在画nwell
pmos是直接拿内建的
希望高手大大能帮忙一下小弟>"<
--
※ 发信站: 批踢踢实业坊(ptt.cc)
◆ From: 140.123.112.130
1F:推 BuBuChen:他不是告诉你pick-up>30um吗?我猜你well里没加pick-up 08/03 13:08
2F:推 BruceBowen12:pick-up 是什麽呀?我还真的都没用耶 08/03 13:53
3F:推 points333:你没画VDD吧 VDD的OD到PMOS的OD 要在30um之内 08/03 21:48
4F:推 ilovecatch:nwell 没包到 body 08/03 23:24
5F:推 BuBuChen:n-well要打contact接到vdd 08/04 00:48
6F:推 BruceBowen12:我是直接从pmos拉线接到vdd的 应该是不用打contact 08/06 13:32
7F:→ BruceBowen12:而且我nwell把pmos全包起来了vdd和gnd也都在30um内 08/06 13:34
8F:→ BruceBowen12:请问这到底是什麽原因 08/06 13:36
9F:推 coa481:如果你body是用guard_ring来拉,那就代表你的body离MOS太远 08/06 18:25
10F:→ coa481:想办法在其他地方画guard_ring,再用metal接起来即可 08/06 18:26
11F:→ coa481:pick-up其实就是指body 08/06 18:27
12F:推 BruceBowen12:我也没有画body 我laker真接拿内建好的 body还需要另 08/07 05:20
13F:→ BruceBowen12:外画吗? guard_ring是怎麽用的呢? 之前画也全用内建 08/07 05:21
14F:→ BruceBowen12:的 都还可以用>"< 08/07 05:22
15F:推 usefun:我是加整排contact、vdd相接,蟋M後n-well把整个pmos包起来 08/07 10:17